Rcctifier voltage calculation formula

How to Specify HT Windings for various rectifier configuration options


The voltage and current ratings for the HT winding can be calculated from the dc voltage and current using the formula below appropriate to your rectifier and smoothing circuit. The power rating for determining the size of the transformer is shown below as Pac (Watts).

The formulae below allowances for the voltage difference due to the wave form factor. The voltage drop across the diodes and the resistance of the choke must be allowed for. We specify the Vac on full load so you do not need to allow for resistance of the transformer windings.

CAPACITOR INPUT FILTER

Full wave rectifier FULL WAVE

Vac = Vdc x 1.41

Iac = Idc

Pac = Pdc x 1.41

bridge rectifier BRIDGE

Vac = Vdc x 0.71

Iac = Idc x 1.61

Pac = Pdc x 1.14

CHOKE INPUT FILTER (Special choke must be used)

Choke input filter full wave

FULL WAVE

Vac = Vdc x 2.22

Iac = Idc x 0.65

Pac = Pdc x 1.44


Choke input filter gridge rectifier
BRIDGE

Vac = Vdc x 1.11

Iac = Idc x 1.06

Pac = Pdc x 1.18

E A Sowter Ltd.
The Boatyard, Cullingham Road
IPSWICH IP1 2EG England
Calculate rectifier output voltage Tel: +44(0)1473 252794
Fax: +44(0)1473 236188